Motor TECO Definite Purpose

Categories ,
Brand:

Motor TECO Definite Purpose

Wash Down Duty Motors Type Code: AEHECW
Wash Down Duty Motors Low Voltage Squirrel Cage Motors Foot Mounted with C-Face Flange TEFC, NEMA T-Frame Design B or C Cast Iron Frame Output 3 ~ 10 HP Pole (Speed) 2, 4 Voltage 230/460V Frequency (Hz) 60 Frame Size 182TC ~ 215TC Protection Enclosure: IP 55 Design Standards: NEMA MG-1, MG-13 Environment: non-hazardous, high humidity and regularly exposed to high pressure water wash down. Stator Insulation: Class F insulation, B rise SF 1.15

Type Code: AEGACW / AEGAFW /AETACW
Wash Down Duty Motors TEFC T-frame, Design B Output 1/2 ~ 10HP Pole (Speed) 2 ~ 4 Voltage 230/460V (usable on 208V at 1.0 SF) Frequency (Hz) 60 Frame Size 56C ~ 215TC Protection Enclosure TEFC, IP 55 Design Standards: NEMA MG-1, MG-13 Environment: non-hazardous, high humidity and regularly exposed to high pressure water wash down. Stator insulation: Class F Insulation, B rise SF 1.15. External surface: rust-proof primer finished with USDA approved white epoxy paint. Test procedure: ANSI/IEEE-112 Method B and full voltage measuring starting performance.

Type Code: AEGECW /AETECW / AEGEFW
Wash Down Duty Motors 3-Phase Induction Motors TEFC T-frame, Design B Output 1/2 ~ 2HP Pole (Speed) 2 ~ 4 Voltage 230/460V (usable on 208V at 1.0 SF) Frequency (Hz) 60 Frame Size 56C ~ 145TC Protection Enclosure TEFC, IP 44 Design Standards: NEMA MG-1, MG-13 Environment: non-hazardous, high humidity and regularly exposed to high pressure water wash down. Stator insulation: Class F Insulation, B rise SF 1.15.

Type Code: AENCFW /AENCCW /AENVCW
Wash Down Duty Motors Low Voltage Squirrel Cage Motors TENV, NEMA T-Frame Design B, Rolled Steel Frame Output 1/2 ~ 10 HP Pole (Speed) 2, 4 Voltage 230/460V Frequency (Hz) 60 Frame Size 56C ~ 215 Protection Enclosure: IP 55 Design Standards: NEMA MG-1, MG-13 Environment: non-hazardous, high humidity and regularly exposed to high pressure water wash down. Stator Insulation: Class F insulation, B rise SF 1.15

Non Sparking Motors Type Code: AEEBXC /AEVBXC
Non-Sparking 3-phase Induction Motors TEFC T-Frame Design B or N Output 1 ~ 250HP (0.75 ~ 185 KW) Pole (Speed) 2 ~ 8 Voltage below 690V Frequency (Hz) 50, 60 Frame Size 80~315MC Protection Enclosure IP 55 Design Standards: BS 5000 Part 16; BS EN60034, BS 4999 Environment: Zone 2, Group II Hazardous Stator insulation: Class F Insulation

Pole Change Motors Type Code: AECP constant torque, constant power
AEPP variable torque Pole (Speed) Change Induction Motors TEFC, Squirrel Cage (High Voltage & Output 15,000HP max. are available per request.) Output 0.25/0.125 ~500/250 HP (for constant torque output) 0.25/0.25 ~ 400 HP ¡@¡@(for constant HP output) Pole (Speed) 2/4 ~ 8/16 Voltage 220V, 380V, 440V Frequency (Hz) 50, 60 Frame Size 63 ~ 450MB Protection Enclosure IP 44 Design Standards: IEC, BS, JEC Environment: non-hazardous Stator insulation: Class B or F Insulation

Long Shaft Motors Type Code: AEVFLR, AEVFLS, AEUE8R
AEVFLR, AEVFLS, AEUE8R Output 1/2 ~ 100HP Pole (Speed) 2 ~ 8 Voltage 220V, 380V, 440V, 460V Frequency (Hz) 50, 60 Frame Size 63 ~ 250M Protection Enclosure IP 44 (IP54, IP55 Options)

Double Shaft Motors Type Code: AEEFSA
Output 1/4 ~ 270HP Pole (Speed) 2 ~ 8 Voltage below 600V Frequency (Hz) 50, 60 Frame Size 63 ~ 315M Protection Enclosure IP 54

Cooling Fan Motors Type Code: AEMC TOP
Output 1/8 ~ 10 HP Pole (Speed) 4 ~ 10 Voltage below 600V Frequency (Hz) 50, 60 Frame Size 63 ~ 132 Protection Enclosure IP 54

High Temperature Resistant (Smokespill) Motors Type Code: AEEBYH / AEVBYH
High Temperature-Resistant 3-phase induction motors BS Design Low Voltage Squirrel Cage WFR approved. Output 1 ~ 250 HP, 45 ~ 185KW Pole (Speed) 2 ~ 8 Voltage below 600V Frequency (Hz) 50, 60 Frame Size 80 ~ 315MB Protection Enclosure IP 54 Design Standards: Meet BS 7346 Part 2, 1990 Specification. Environment: Stator insulation: Class H insulation Temp/Time: 300¢J, 60 min. D class 400¢J, 120 min. E class

Oil Well Pump Motors Type Code: AEEAFP TOP
Low Voltage Oil Well Pump Motors, Triple Rated, TEFC, NEMA Design D, Cast Iron Frame Output 7.5 ~ 50 HP Pole (Speed) 6 Voltage 460V, 575V Frequency (Hz) 60 Frame Size 250T ~ 400T Protection Enclosure IP 54 Design Standards: NEMA MG-1, MG-13 Environment: non-hazardous Stator Insulation: Class F insulation, F rise at SG 1.15 or SF 1.0 Fully garded with Rodent screens. Oversized bearings selected for Belt-drive application. Grounding Terminals on Frames and Inside Conduit Box. Thermal Protectors Embedded in Winding in each phase. Stainless Steel Nameplate.

Type Code: ASFAFP
Low Voltage Oil Well Pump Motors ODP, NEMA Design D, 5 ~ 8% slip, Cast Iron Frame, Design D Output 5 ~ 150 HP Pole (Speed) 6 Voltage 230/460/796V Frequency (Hz) 60 Frame Size 215T~445T Protection Enclosure IP 22 Design Standards: NEMA MG-1, MG-13 Environment: non-hazardous Stator insulation: Class F Insulation, 1.15 SF. Cast Iron Frame, End Brackets & Oversized Conduit box. Fully guarded with Rodent screens. Oversized bearings selected for Belt-drive application. Grounding Terminals on Frames and Inside Conduit Box Thermal Protectors Embedded in Winding in each phase.

Crusher Duty Motors Type Code: AEEAGD
Standard 3-Phase Induction Motors Low Voltage Squirrel Cage Output 200 ~ 500 HP Pole (Speed) 2~8 Voltage 460V, 575V Frequency (Hz) 60 Frame Size 5007C ~ 5808C Protection Enclosure IP55 Design Standards: NEMA MG-1, MG-13 Environment: non-hazardous Stator insulation: Class F Insulation, 1.15 SF.

Features:
Wash Down Duty Motors Non Sparking Motors Pole Change Motors Long Shaft Motors Double Shaft Motors Cooling Fan Motors High Temperature Resistant(Smokespill)Motors Oil Well Pump Motors Crush Duty Motors

SPECIFICATION MOTOR TECO DEFINTE PURPOSE

Standard Mounting Voltage Enclosure Motor type Description
NEMA Horizontal LV TEFC AEEAGD   Crusher Duty Motors
ODP ASFAFP   Oil Well Pump Motors
TEFC AEEAFP
AEHECW   Wash Down Duty Motors
(Cast Iron Frame)
AEGACW Wash Down Duty Motors
AEGAFW (Rolled Steel Frame)
AETECW
AEGECW
AEGEFW
TENV AENCFW
AENCCW
Vertical AENVCW
TEFC AETACW
IEC,BS, AS,JIS, JEC,CNS Horizontal AEEBXC   Non Sparking Fan
Vertical AEVBXC
Horizontal AEEBYH   Smokespill Motors
Vertical AEVBYH
Horizontal AECP/AEPP   Pole Change Motors
AEEFSA   Double Shaft Motors
AEMC   Cooling Fan Motors
Vertical AEVFLR   Long Shaft Motors

Reviews

There are no reviews yet.

Be the first to review “Motor TECO Definite Purpose”

Your email address will not be published. Required fields are marked *

ขอใบเสนอราคา/Request a quote

  • Hidden
  • This field is for validation purposes and should be left unchanged.