Pressure Transmitter DANFOSS DST P92S Series SIL2 is an OEM-grade pressure transmitter engineered for both mobile and industrial hydraulic systems. It is designed for applications that require functional safety compliance, supporting SIL2 and PL d requirements as part of a safety-related system architecture.
With a wide measuring range from 0–10 bar up to 0–1200 bar, the series offers dual-output signal options (e.g., 4–20 mA / 20–4 mA). Wetted parts are made of stainless steel, and the robust design is rated to IP67, making it a reliable choice for demanding hydraulic applications and heavy-duty machinery where long-term stability is essential.
DANFOSS DST P92S Series SIL2 is a pressure transmitter developed for OEM integration in both mobile hydraulics and industrial hydraulic installations. It is built to deliver durability, consistent performance, and dependable measurement accuracy—while supporting functional safety concepts for systems designed to meet SIL2 (IEC 61508:2010) and/or PL d (EN ISO 13849-1:2015), depending on the overall system design.
The DST P92S Series is well suited to harsh operating conditions, including high-pressure hydraulics, heavy machinery, mobile equipment, and production environments that demand fast, stable pressure feedback. Its strong long-term stability helps reduce control drift and supports reliable operation over time.
For media compatibility and endurance, wetted parts are manufactured from stainless steel and paired with a Viton seal (per medium-contact material specification). The housing is designed to withstand demanding environments, features an IP67 protection rating, and meets EMC requirements for stable integration with modern control systems.
Explore related products in the Pressure Transmitter category.
| Accuracy (incl. non linearity, hysteresis and repeatability) | < 0.5% FS 1) |
| Overall accuracy under reference conditions | +/- 1% FS [0 – 85 °c] |
| +/- 1,5% FS [-25 – 0 °c] | |
| +/- 2,5% FS [-40 – -25 °c] | |
| Long-run stability | <0,2% FS p.a. |
| Response time liquids (10 – 90%) | 2 ms |
1) 1, Load 100 Ω, temperature in steady state, accuracy valid for output 1 for 4 – 20 mA
| Standard pressure [bar] | 40 | 60 | 100 | 160 | 250 | 400 | 600 |
| Overload pressure [bar] | 80 | 120 | 200 | 320 | 500 | 800 | 1200 |
| Burst pressure [bar] | 400 | 600 | 1000 | 1600 | 2500 | 4000 | >4000 |
| Media temperature range | – 40 – 125 °C | |
| Operating temperature range | -40 – 85 °C | |
| Storage temperature range | -40 – 100 °C | |
| Voltage supply | 9 – 32 V DC, alloable ripple @50Hz: 10% (for current output) | |
| 5V ±10% (for ratiometric voltage output) | ||
| Electrical Protection | Short circuit protected, signal on GND/VCC and reverse polarity protection | |
| Electric Magnetic Compatibility Directive [EMC] | 2014/30/EU | |
| DIN EN 61326-1 | ||
| DIN EN 61326-2-3 | ||
| DIN EN 61326-3-1 | ||
| EMC | E1 type approval: All vehicle types with a 12 V or 24 V – electrical wiring and battery (-) at the body | |
| Vibration stability | 20 g | EN60068-2-6 |
| Shock mechanical | 500 g | EN60068-2-27 |
| Enclosure | 1.4301/ PBT-GF30 | |
| Material with medium contact | 1.4548/Viton | |
| Weight | 50 g | |
| Enclosure | IP67 | |
| Machinery Directive [MD] | 2006/42/EC | |
| IEC 61508:2010 | SIL 2 | Safety related subsystem, type B |
| 1oo1 architecture | SFF 95.8% 4-20mA / 93,1% | |
| ratiometric (incl. control unit) | ||
| HFT 0 | PFH 6.1*10-9 (4-20 mA) / 4.9*10-9 | |
| (ratiometric) | ||
| EN ISO 13849-1:2015 | PL d | CCF 70 points |
| Category 2 | MTTFd high >100 years | |
| DC medium (incl. control unit) | ||
| Safety function | Safety conversion of the measured pressure into two proportional opposing current signals. Refer also to the Safety guide. | |


|
Type |
Measuring range | Pressure connection | Electrical connection | Electrical output | Code no |
| DST P92S | 0 – 40 bar | G1/4 DIN 3852-E | M12 | 4-20mA / 20-4mA | 078G1000 |
| DST P92S | 0 – 60 bar | G1/4 DIN 3852-E | M12 | 4-20mA / 20-4mA | 078G1001 |
| DST P92S | 0 – 100 bar | G1/4 DIN 3852-E | M12 | 4-20mA / 20-4mA | 078G1002 |
| DST P92S | 0 – 160 bar | G1/4 DIN 3852-E | M12 | 4-20mA / 20-4mA | 078G1003 |
| DST P92S | 0 – 250 bar | G1/4 DIN 3852-E | M12 | 4-20mA / 20-4mA | 078G1004 |
| DST P92S | 0 – 400 bar | G1/4 DIN 3852-E | M12 | 4-20mA / 20-4mA | 078G1005 |
| DST P92S | 0 – 600 bar | G1/4 DIN 3852-E | M12 | 4-20mA / 20-4mA | 078G1006 |