DANFOSS RT Series Pressure Switches are high-quality pressure control devices designed for general industrial systems, marine applications, and boiler installations. They provide accurate control of both pressure and differential pressure, and are built to operate reliably across a wide temperature range from -50°C to 150°C.
Certified to SIL 2 in accordance with IEC 61508 and rated IP66 for dust and water ingress protection, the RT Series features a rugged construction and long service life—ideal for applications where dependable performance is essential.
DANFOSS RT Series pressure switches are widely trusted pressure control devices used across industries worldwide. They are designed for pressure switching (pressure switch), differential pressure switching (differential pressure switch), and control with an adjustable neutral zone. The RT Series is well suited for installation in steam systems, refrigeration systems, boilers, and heavy-duty machinery where dependable performance is essential.
| Designation | RT pressure switches |
| Ambient temperature | In general: -50 to 70 °C |
| Diaphragm version: -10 to 70 °C | |
| TÜV approved: -40 to 70 °C | |
| Media temperature | In general: -50 to 100 °C |
| Diaphragm version: -10 to 90 °C | |
| TÜV approved: -40 to 150 °C | |
| Contact system | Single-pole changeover switch (SPDT), see Figure 22 |
| Contact load | Alternating current: AC-1: 10 A, 400 V; AC-3: 4 A(1), 400 V |
| AC-15: 3 A(1), 400 V | |
| Contact material: AgCdO | Direct current: |
| DC-13: 12 W, 220 V (see Figure 23) | |
| Special contact system | See spare parts and accessories |
| Cable entry | 2 PG 13.5 for 6–14 mm diameter cables |
| Solid / stranded | 0.2–2.5 mm2 |
| Flexible, without ferrules | 0.2–2.5 mm2 |
| Flexible, with ferrules | 0.2–1.5 mm2 |
| Tightening torque | Max. 1.5 Nm |
| Enclosure | IP66 in accordance with IEC 529 and EN 60529. Units supplied with external reset: IP54. The housing is made of bakelite (DIN 53470). The cover is made of polyamide. |



(1) Preferred versions.
(2) Supplied with ø6 / ø10 mm weld nipple.
(3) With seal cap.

(1) Preferred versions.
(2) Supplied with ø6 / ø10 mm weld nipple.

(1) Preferred versions.
(2) Supplied with ø6 / ø10 mm nipple.
(3) Non-snap action contacts
(4) With SPST and SPDT contact system for alarm and cut-off function at 0.8 and 1 bar.
The designation letters mean:

(1) Preferred versions.